GB
16
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
37 **
25 **
45 **
28-30 **
20 **
35 **
20
17
25
Fast
(Large) (R)
Semi Fast
(Medium) (S)
Auxiliary
(Small) (A)
Supply
pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
75
55
3.00
1.65
1.00
Nom. Red.
0.70
0.40
0.40
By-pass
1/100
(mm)
40
30
30
Nozzle
1/100
Flow*
g/h
(mm) ***
86
64
50
Nozzle
1/100
Flow*
l/h
(mm)
116
96
71
286
157
95
218
120
73
**
214
118
71
* At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/kg.
*** Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
R
S
S
A
R
S
A
S
PSC 04 T PSC 04 OV