6
AUS
Adapting to different types of gas
It is possible to adapt the appliance to a type of
gas other than the default type (this is indicated on
the rating label on the cover).
Adapting the hob
Replacing the nozzles for
the hob burners:
1. Remove the hob grids
and slide the burners off
their seats.
2. Unscrew the nozzles
using a 7 mm socket
spanner (
see figure
), and replace them with
nozzles suited to the new type of gas (
see
Technical Specifications table
).
3. Replace all the components by following the
above instructions in reverse.
Adjusting the hob burners’ minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory
screw, which is positioned inside or next to the tap
pin, until the flame is small but steady.
! If the appliance is connected to a liquid gas
supply, the regulatory screw must be fastened as
tightly as possible.
3. While the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the flame is not
extinguished.
! The hob burners do not require primary air adjustment.
! After adjusting the appliance so it may be used
with a different type of gas, replace the old rating
label with a new one that corresponds to the new
type of gas (these labels are available from
Authorised Technical Assistance Centres).
! Should the gas pressure used be different (or
vary slightly) from the recommended pressure, a
suitable pressure regulator must be fitted to the
inlet hose in accordance with current national
regulations relating to “regulators for channelled
gas”.
Post Installation Checks
Perform post installation checks and ensure proper and
safe operation before leaving. Test all burners
individually and in combination.
Leak Check
• Ensure all gas control knobs are in the Off position.
• Ensure the gas supply is switched on.
• Spray a solution of soapy water onto all gas joints as
well as the full length of any flexible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED FLAME
IN CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off,
check all connections and retest. If satisfactory
operation cannot be achieved, contact place of
purchase or their appointed agent for service.
Flame check
Turn each burner on, and ensure that the flame is blue
with minimal yellow tipping. If there is significant yellow
tipping, flame lift off or excessive noise, check pressure
and adjust at the regulator if necessary.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for service.
Igniter operation
Check that the igniter for each burner successfully
ignites the gas.
If an igniter fails to work, first remove the plug from the
electrical power outlet, and then check that all the
electrical connections are in place.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for service.
Low flame setting
Check the low flame setting for each hob burner to
ensure that the minimum flame will not be extinguished
by air draughts.
• Light the burner.
• Turn the control until it engages in the minimum
position.
• Ensure the flame is stable and will not be
extinguished by air draughts.
To adjust the minimum flame:
Follow the procedure described in the gas conversion
instruction.
DO NOT MODIFY THIS APPLIANCE IN ANY WAY,
OTHER THAN AS DESCRIBED IN THESE
INSTRUCTIONS.