4
Burner and nozzle characteristics
K3M11S/EX - K3M11/EX
S
R
A
Ø180
Table 1 Liquid Gas
Burner Diameter
(mm)
By-Pass
1/100
Nozzle
1/100
Flow
g/h
(mm) (mm) nominal minim
Fast
(Large)(R)
100 41 87 220 50
Semi Fast
(Medium)(S)
75 30 70 140 25
Auxiliary
(Small)(A)
51 30 52 65 25
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
30
25
35
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
Comentários a estes Manuais